What to do if the vulcanizer gets water

Mar 31, 2023

השאר הודעה

If water enters the heating plate due to improper operation during use, you should first contact the manufacturer for maintenance. If emergency repair is needed, open the cover on the heating plate, pour out the water first, then set the electric control box to manual operation, heat up to 100°C, keep the constant temperature for half an hour, dry the circuit, and then Carry out belt gluing under manual state. At the same time, the manufacturer should be contacted in time to replace the circuit as a whole.

 

If the vulcanizer does not need to be used for a long period of time, the heating plate should be heated every half a month (the temperature is set at 100°C), and the temperature should be kept for about half an hour.

 

After each use, the water in the hydraulic plate should be drained, especially in winter, if the water cannot be drained, it will often lead to premature aging of the rubber of the hydraulic plate and reduce the service life of the hydraulic plate.

The correct way to release water is to carry out after the vulcanization heat preservation is completed and before the vulcanizer is disassembled. If water is released after the machine is disassembled, the water in the water pressure plate may not be completely discharged. Regarding the flat vulcanizing machine as a conveyor belt joint tool, it should be maintained and maintained like other tools during and after use to prolong its service life.

 

Please check whether the pressure bag is damaged in time, any mopping friction, cutting, folding and other improper operations will cause damage to the pressure bag. After the pressure bag is damaged, it may leak water, air leak, or be completely destroyed when it is under pressure. Pay special attention to where the pressure bag is in contact with the water or gas nozzle. Inspect all pressurized hoses and fittings for wear, leaks, or other damage that could cause hoses and fittings to fail under pressure. Check all cables for punctures, wear, and aging, paying particular attention to "stress points" such as between cables and connectors. If necessary, check and adjust the temperature controller. Check all indicator lights and replace if damaged. If the vulcanizer is equipped with a hydraulic pump, check the liquid storage tank, pump body and all connections for leaks. The mesh on the filter should be removed for cleaning. Check the pressure gauge to ensure its accuracy. Lubricate the pump body.

 

The above are the suggestions provided by Qingdao Beishun Environmental Protection Technology Co., Ltd. If you want to buy a vulcanizing machine, you are welcome to choose our products. We will provide you with one-stop service and very suitable quotation. Our service personnel have rich professional knowledge and look forward to cooperating with you.